Neon Infotech Logo Neon Infotech Logo Neon Infotech Neon Infotech
Home | Sitemap | Contact | Careers
About Solutions Products Services Feedback Search
Duct Size

Duct Size 6.0 is an engineering software program that performs HVAC (Heating, Ventilation, and Air Conditioning) duct design based upon the ASHRAE 2001 Fundamentals. This program allows the user to input a wide variety of information about a duct system, and it displays numerous reports such as duct dimension and airflow breakdown report, a material list, a heat loss breakdown report, friction loss breakdown report, sound-power breakdown report and many others. In addition, the user can import a single-line drawing from AutoCad 2000 to 2005 and export it back to AutoCad as a double-line or 3-D drawing.

The purpose of this software is to provide the user with a total duct system analysis so that they can properly size the duct work and the fan that serves the duct system. This program is geared specifically toward the HVAC engineer, architect, design/build mechanical contractor, and building maintenance supervisor.

   
Features
The following is a list of features available in Duct Size 6.0:

New Features

  • The Duct Size 6.0 software has been entirely re-written to take advantage of the latest programming and back-end database technologies. In addition, the entire ASHRAE fitting database of over 200 fittings has been incorporated into the software, including pressure loss data and pictures.
  • A new and improved user interface (UI) has been designed making the input process much faster and more intuitive than previously. This improved UI includes a tree-like navigation area that allows the user to view all duct systems, fans, and duct nodes.
  • Within the navigation area, basic information such as airflow, dimensions can be displayed next to each duct node allowing the user to quickly view important information about the entire duct system.
  • The user can copy duct systems within the same project and also copy sections of duct nodes within the same duct system.
  • The user can easily replicate entire projects so as to reuse common information.
  • An unlimited number of duct system templates can now be created so that the user can create new duct systems using common data from the templates.
  • Includes new "Suggest a fitting" technology that allows Duct Size to suggest a duct fitting based upon the current configuration of duct runs
  • Can model duct systems based upon the constant velocity method of calculations
  • Input checks have been incorporated so the user can confirm that inputs are valid prior to calculating.
  • Includes many more reports including addtional sound-power and attenuation reports.
  • All input and output data can be exported to Microsoft Word and Excel templates.
  • Reports can be exported to XML format so that they can be shared with others across networks and operating systems other than Windows.
  • Can import from AutoCad 2004/2005 DXF files
  • Can export to AutoCad 2004/2005 DXF files
  • Can import and export information from AutoCad Building Systems
  • An additional 300 cities have been added to the weather database making the total 800.
  • . . . and more.


Standard Inputs

  • Input up to 1000 duct nodes per duct system
  • Input multiple duct systems per duct project
  • Specify duct size calculations according to constant friction, constant velocity, or static regain methods.
  • Model existing duct size systems to determine total static pressure loss and fan size.
  • Specify fan upstream and downstream pressure losses
  • Specify global duct system values such as material type, duct shape, and liner and insulation widths
  • Specify minimum and maximum allowable values such as duct dimensions, velocities, and duct lengths
  • Specify fan inlet and outlet characteristics such as sizes and air velocities
  • Specify sound-related fan inputs such as fan efficiency, RPM, HP, and octave band frequencies
  • Specify individual node characteristics such as length, fitting or equipment type, tap type, roughness, material, shape, insulation width, liner width, seal class, and much more . . .


Types of Built-In Data Included

  • Data for 200+ ASHRAE fittings including pressure loss info. and pictures
  • Data for HVAC duct size equipment such as diffusers, grilles, VAV boxes, and fan-powered mixing boxes
  • Fan filter data including pressure losses
  • Duct material types
  • Duct gage and density data
  • U-Value and velocity data to determine heat loss/gain throughout the duct system
  • Fan sound power data
  • 800 city weather database including the United States and the entire world


Outputs

  • Includes duct size and airflow breakdown report
  • Includes total fan pressure report
  • Includes duct pressure loss breakdown report
  • Includes duct critical pressure path report
  • Includes duct leakage breakdown report
  • Includes duct heat gain/loss breakdown report
  • Includes cumulative sound analysis by node report
  • Includes room sound pressure level analysis report
  • Includes duct weight and gage breakdown report
  • Includes duct material list report
  • Includes duct violations report
  • Includes capability to export to custom Microsoft Word and Excel documents
  • Can export to html and text files
  • Can export to XML files


Additional Features

  • Support for both English and Metric units.
  • Simple mathematical capabilities at every input.
  • Global data editing of all inputs.
  • Can import single-line DXF drawings from AutoCad 2000 to 2005
  • Can export double-line and 3-D DXF drawings to AutoCad 2000 to 2005
  • Can import and export data to AutoCad Building systems 2005

 

For more information please visit Carmel Duct Size

 
Neon Infotech – Your Dependable Technology Partner
 
 
(Site best viewed at IE 5.0+ and NS6.0+) Copyright © 2005-2006 Neon Infotech (All rights reserved)