Duct Size 6.0
is an engineering software program that performs HVAC
(Heating, Ventilation, and Air Conditioning) duct
design based upon the ASHRAE 2001 Fundamentals. This
program allows the user to input a wide variety of
information about a duct system, and it displays numerous
reports such as duct dimension and airflow breakdown
report, a material list, a heat loss breakdown report,
friction loss breakdown report, sound-power breakdown
report and many others. In addition, the user can
import a single-line drawing from AutoCad 2000 to
2005 and export it back to AutoCad as a double-line
or 3-D drawing.
The purpose of this software is to provide
the user with a total duct system analysis
so that they can properly size the duct work
and the fan that serves the duct system. This
program is geared specifically toward the
HVAC engineer, architect, design/build mechanical
contractor, and building maintenance supervisor.
|
|
| |
|
| Features |
| The following is a
list of features available in Duct Size 6.0: |
New Features
-
The Duct Size 6.0 software
has been entirely re-written to take advantage
of the latest programming and back-end database
technologies. In addition, the entire ASHRAE
fitting database of over 200 fittings has
been incorporated into the software, including
pressure loss data and pictures.
-
A new and improved user
interface (UI) has been designed making
the input process much faster and more intuitive
than previously. This improved UI includes
a tree-like navigation area that allows
the user to view all duct systems, fans,
and duct nodes.
-
Within the navigation
area, basic information such as airflow,
dimensions can be displayed next to each
duct node allowing the user to quickly view
important information about the entire duct
system.
-
The user can copy duct
systems within the same project and also
copy sections of duct nodes within the same
duct system.
-
The user can easily replicate
entire projects so as to reuse common information.
-
An unlimited number of
duct system templates can now be created
so that the user can create new duct systems
using common data from the templates.
-
Includes new "Suggest
a fitting" technology that allows Duct
Size to suggest a duct fitting based upon
the current configuration of duct runs
-
Can model duct systems
based upon the constant velocity method
of calculations
-
Input checks have been
incorporated so the user can confirm that
inputs are valid prior to calculating.
-
Includes many more reports
including addtional sound-power and attenuation
reports.
-
All input and output
data can be exported to Microsoft Word and
Excel templates.
-
Reports can be exported
to XML format so that they can be shared
with others across networks and operating
systems other than Windows.
-
Can import from AutoCad
2004/2005 DXF files
-
Can export to AutoCad
2004/2005 DXF files
-
Can import and export
information from AutoCad Building Systems
-
An additional 300 cities
have been added to the weather database
making the total 800.
-
. . . and more.
|
Standard Inputs
-
Input up to 1000 duct
nodes per duct system
-
Input multiple duct systems
per duct project
-
Specify duct size calculations
according to constant friction, constant
velocity, or static regain methods.
-
Model existing duct size
systems to determine total static pressure
loss and fan size.
-
Specify fan upstream
and downstream pressure losses
-
Specify global duct system
values such as material type, duct shape,
and liner and insulation widths
-
Specify minimum and maximum
allowable values such as duct dimensions,
velocities, and duct lengths
-
Specify fan inlet and
outlet characteristics such as sizes and
air velocities
-
Specify sound-related
fan inputs such as fan efficiency, RPM,
HP, and octave band frequencies
-
Specify individual node
characteristics such as length, fitting
or equipment type, tap type, roughness,
material, shape, insulation width, liner
width, seal class, and much more . . .
|
Types of Built-In Data Included
-
Data for 200+ ASHRAE
fittings including pressure loss info. and
pictures
-
Data for HVAC duct size
equipment such as diffusers, grilles, VAV
boxes, and fan-powered mixing boxes
-
Fan filter data including
pressure losses
-
Duct material types
-
Duct gage and density
data
-
U-Value and velocity
data to determine heat loss/gain throughout
the duct system
-
Fan sound power data
-
800 city weather database
including the United States and the entire
world
|
Outputs
-
Includes duct size and
airflow breakdown report
-
Includes total fan pressure
report
-
Includes duct pressure
loss breakdown report
-
Includes duct critical
pressure path report
-
Includes duct leakage
breakdown report
-
Includes duct heat gain/loss
breakdown report
-
Includes cumulative sound
analysis by node report
-
Includes room sound pressure
level analysis report
-
Includes duct weight
and gage breakdown report
-
Includes duct material
list report
-
Includes duct violations
report
-
Includes capability to
export to custom Microsoft Word and Excel
documents
-
Can export to html and
text files
-
Can export to XML files
|
Additional Features
-
Support for both English
and Metric units.
-
Simple mathematical
capabilities at every input.
-
Global data editing of
all inputs.
-
Can import single-line
DXF drawings from AutoCad 2000 to 2005
-
Can export double-line
and 3-D DXF drawings to AutoCad 2000 to
2005
-
Can import and export
data to AutoCad Building systems 2005
|
For more information please visit
Carmel
Duct Size
|