| Feature |
C E |
S E |
H E |
T E |
P E |
Core |
Super |
Power |
EEPlant |
| Fault Analysis |
|
|
|
|
|
|
|
|
|
| A.C. Short Circuit – 3 Phase ANSI/IEEE |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| A.C. Short Circuit – IEC 909 |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| A.C. Short Circuit – 1 Phase |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Arc Heat Arc Flash Energy–NFPA 70E 2004
&IEEE 1584EE |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| A.C. Short Circuit -IEC 363 |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| DC Short Circuit |
|
|
|
|
|
|
|
¤ |
¤ |
| Protection Coordination |
|
|
|
|
|
|
|
|
|
| Device Coordination- 3 Phase |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Device Coordination-1 Phase |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Device Coordination- DC |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Validated Protective Device Curve Library |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Impedance Relay Coordination |
|
|
|
|
|
|
|
|
¤ |
| Power Flow Analysis |
|
|
|
|
|
|
|
|
|
| AC Power Flow –3Phase |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| AC Power Flow- 1Phase |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| AC Multi Motor Starting LF |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Ac Advanced Power Flow with Motor Torque |
|
|
|
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| AC Unbalanced Load Flow- 3 Phase |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| AC Voltage Profile |
|
|
|
|
|
|
|
¤ |
¤ |
| AC Active Optimal Power Flow |
|
|
|
|
¤ |
|
|
¤ |
¤ |
| AC Reactive Optimal Power Flow |
|
|
|
|
|
|
|
¤ |
¤ |
| AC/DC Integrated Load Flow |
|
|
|
|
|
|
|
¤ |
¤ |
| AC/DC Load Flow with DC Lines |
|
|
|
|
|
|
|
¤ |
¤ |
| DC Power Flow |
|
|
|
|
|
|
|
¤ |
¤ |
| Load Forecasting |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| Power Quality Analysis and Mitigation |
|
|
|
|
|
|
|
|
|
| Power Factor Correction |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Harmonic Analysis with automatic Filter Sizing |
|
|
¤ |
|
¤ |
|
|
¤ |
¤ |
| Distribution and Substation Reliability Analysis |
|
|
|
|
|
|
|
¤ |
¤ |
| Capacitor Sizing and Optimization |
|
|
|
|
|
|
|
¤ |
¤ |
| Dynamic Behavior Simulation |
|
|
|
|
|
|
|
|
|
| Motor Torque and Performance |
|
¤ |
|
¤ |
¤ |
|
¤ |
¤ |
¤ |
| Advance Transient Stability with Model Builder |
|
|
|
¤ |
¤ |
|
|
¤ |
¤ |
| Electromagnetic Transient Analysis – EMTAP® |
|
|
|
|
|
|
|
¤ |
¤ |
| Design Optimization |
|
|
|
|
|
|
|
|
|
| Electrical Schedules |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
¤ |
| Motor Parameter Estimations |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| Ground Grid Design Finite Different with 3D Plotting |
|
¤ |
|
|
¤ |
|
¤ |
¤ |
¤ |
| Cable Pulling in 3D |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| Shielding Effectiveness |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| Sizing Optimization |
|
|
|
|
|
|
|
|
|
| Battery Sizing |
|
|
|
|
|
|
|
¤ |
¤ |
| Cable Ampacity N-M and IEC |
|
¤ |
|
|
¤ |
|
¤ |
¤ |
¤ |
| Generator Set Sizing |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Transformer Sizing |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Wire and Conduit Sizing |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Bare Wire Sizing |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Short Line Parameters |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Transmission Line Constants |
|
|
|
|
|
¤ |
¤ |
¤ |
¤ |
| Cable Tray Analysis |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| Transmission Line Sag and Tension |
|
|
|
|
|
|
¤ |
¤ |
¤ |
| |
Add-on Features available:
- Impedance Relay Co-ordination
- Advanced Transient Stability (Includes Advanced
Power Flow)
- Harmonic Analysis
- EMTAP
- AC Voltage Profile
- DC System
- Distribution Reliability
- Ground Grid Design
- Capacitor Sizing and Optimization
- Load Forecasting
|